UPS-IND MR1 1300

Uninterruptible Power Supply (UPS)

UPS-IND MR1 1300

Uninterruptible Power Supply (UPS)
20 ~ 140 kVA
Capacity
+/- 1%
Voltage regulation
2 Year Warranty
Manufactured in Mexico

The modular UPS has been specially designed for sites and data centers. DSP control provides an improved solution with top performance. Integrated with modular design and parallel technology, UPS-IND MR1 simplifies future power expansion

  • On-line double conversion
  • Power factor 1.0
  • Additional slot for SNMP Network or Dry Contacts
  • Dual Input Power Supply (Normal and Bypass)
  • DSP Technology for High Performance and Reliability
  • Scalability for Modules and Parallel Equipment
  • Power Modules and Batteries designed for Hot Swapping
  • Inverter with 3 level IGBT technology
  • High Efficiency, up to 94%.

Uninterrupted Power

Icono rayo
On-line double conversion
Guarantees a clean and stable output voltage at all times, regardless of power supply variations.
Icono rayo
Power factor 1.0
The 1.0 power factor ensures efficiency and performance, optimizing the electrical system.
Icono rayo
DSP technology
Digital Signal Processor (DSP) high precision and fast control for maximum system performance.
Icono rayo
Scalability
4 or 8 Modules (depending on the model) for N+1 or N+ X in the same unit and 2 Units in parallel.
Icono rayo
Inverter with 3 level IGBT
Management with IGBT technology adaptable to higher powers, operating at high speed and higher efficiency.
Icono rayo
High Efficiency
Maximum AC to AC efficiency of 94%.
Icono rayo
Hot Swap
Power Modules and Batteries designed for Hot Swapping.
Icono rayo
Intelligent double slot
Additional slot for SNMP Network or Dry Contacts
Icono rayo
Dual Input
Dual Input Power Supply (Normal and Bypass)

Applications

Audiovisual Systems
Audiovisual Systems
Banks
Banks
Commercial buildings
Commercial buildings
Commercial Security Systems
Commercial Security Systems
IT Servers
IT Servers
Precision Instruments
Precision Instruments
Regional Office Building
Regional Office Building
Telecommunication
Telecommunication

Technical Specifications

Model
UPS-IND MR1 1380 (80 kVA)
UPS-IND MR1 13140 (140 kVA)
Overload Protection Thermal magnetic input circuit breaker and Thermal magnetic bypass circuit breaker
Voltage Range (Vac) 156 to 253 (Line to Line): -29 % , +15 %
Phase Three Phase Star, (3 Phases + Neutral + Ground), optional: Delta (3 Phases + Ground)
Frequency Range (Hz) 40 ~ 70
Input Power Factor ≥ 0.99 at full load, ≥ 0.98 at 50% of the load
Power Modules (20 kW) 4 7+1
THDi ≤ 3% at full load
Model
UPS-IND MR1 1380 (80 kVA)
UPS-IND MR1 13140 (140 kVA)
Capacity (W/ VA) 80000/80000 140000/140000
AC to AC Maximum Efficiency 94 % above 50 % load
Overload Protection Thermal magnetic output circuit breaker
Output Power Factor 1.0
Voltage (Vac) 120/208 or 127/220
Voltage Regulation Range (Vac) ≤+/- 1 % with Balanced Load, ≤ +/- 2 % with Unbalanced Load
Frequency (Hz) 60/50 Hz, autoselect (synchronizable from 40 ~ 70)
Waveform Pure Sinosoidal Wave
Harmonic Distortion THDv ≤ 2% (linear load), ≤ 4% (non-linear load)
Transfer Time (ms) 0.0 ms(True On Line)
Tipo de conexión Three Phase Star, (3 Phases + Neutral + Ground), optional: Delta (3 Phases + Ground)
Overload < 105% continuous, 105% to 110% 60 min., 110% to 125% 10 min., 125% to 150% 60 s.,> 150% immediate switch to Bypass
Model
UPS-IND MR1 1380 (80 kVA)
UPS-IND MR1 13140 (140 kVA)
Voltage (Vdc) Adjustable +/-96 ~ +/-120
Battery Capacity Up to 160 9 Ah 12 V Batteries Without Batteries (External Battery Bank)
Battery Type Lead Acid (Sealed & Maintenance Free)
Full load backup time (min) 5 – 13* 5 – 15*(depending on the Battery Bank)
Maximum Load Current (A) 8 A for each power module (adjustable)
Battery Bank Up to 4 Series (each Series: 4 packs of 10 Batteries) Requires External Bank

* Consult with your Industronic Advisor.

Model
UPS-IND MR1 1380 (80 kVA)
UPS-IND MR1 13140 (140 kVA)
Audible Noise (dB) <<50 ~ 55, at 1 meter
Operating Temperature (°C) 0 ~ 40
Relative Humidity 0 ~ 95% without Condensation
Maximum Operating Altitude (m.a.s.l.) 2,000 al 100%
Cabinet Baked electrostatic Epoxy coated Steel
Dimensions, height x width x depth (mm) 2010 x 600 x 1100
Dimensions, height x width x depth (mm) 926 (with batteries) 537
Model
UPS-IND MR1 1380 (80 kVA)
UPS-IND MR1 13140 (140 kVA)
Inverter 3 level IGBT with PWM (Pulse Width Management) Technology
Rectifier High Efficiency PFC type with IGBT technology
Output Isolation Transformer Optional
Battery Status
Thermal Dissipation (kBTU / h) 20.4 35.8
Internal Bypass Two Bypass Modes: Automatic Static & Manual Bypass Switch for Maintenance
Paralleling 4 Modules for N+1 or N+X in the same unit and 2 Units in parallel 8 Modules for N+1 or N+ X in the same unit and 2 Units in parallel
Certificaciones CE-62040-1, CE 62040-2, ISO 9001:2015, NOM
Interfaz de Comunicación RS232, Puerto USB, 3 señales de salida contacto seco, tarjeta de red SNMP, Ranura adicional para Tarjeta de Red
Pantalla Digital táctil Muestra: Voltaje de entrada y salida, Capacidad de carga, Voltaje de baterías, Mímico de estado operativo, Módulos Operando y LEDS indicadores
Alarmas Batería Baja, Falla de Alimentación, Falla de UPS, Falla de Inversor, Falla de Rectificador, etc.
Protección Batería Baja, Sobrecarga, Corto circuito, Sobretemperatura, etc.