High frequency UPS offers maximum security and back up for demanding industrial applications such as: industrial plants, heavy machinery, robotics and commercial buildings.
|
UPS-IND K
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|
| Capacity (kVA / kW) | 300/270 | 400/360 | 500/450 | 600/540 |
| Input Voltage (V) | 220 / 380, 230 / 400, 240 / 415, 254 / 440, 266 / 460, 277 / 480 | |||
| Overload Protection | Switch & Fuse | |||
| Range (Accepted) | + 15%, – 20% | |||
| Phases | Star: 3 phase star (4 wires + ground) / Delta: (optional) 3 phases (3 wires + ground) | |||
| Frequency | 60 ± 10 % (optional 50 ± 10 % ) | |||
| THDI | ≤ 2% at full load | |||
| Power Factor | ≥ 0.99 | |||
|
UPS-IND K
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|
| Overload Protection | Switch & Fuse | |||
| Output Power Factor | 0.9 (optional 1) | |||
| Voltage (Vca) | 220 / 380, 230 / 400, 240 / 415, 254 / 440, 266 / 460, 277 / 480 | |||
| Voltage Regulation Range | ± 1% (typical) | |||
| Frequency (Hz) | 60 ± 0.2% (optional 50 ± 0.2%) in battery mode | |||
| Wave Form | Pure THDV Sinusoidal Wave ≤ 0.5% (linear load), ≤ 2% (RCD load TP= 0.8 ≤ 6%) | |||
| Transfer Time (ms) | 0.0 (on line) | |||
| Crest Factor | 3 : 1 | |||
| Connection Type | Star (3 phases, 4 wires + ground) | |||
| Overload Capacity | 130% of nominal load for 10 min; 150% for 1 min | |||
|
UPS-IND K
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|
| Voltage (Vcd) | 480 (42 batteries) | |||
| Battery Type | Lead Acid (Open or Sealed) | |||
| Battery Management | Smart Monitor | |||
| Battery Temperature Sensor | Optional | |||
| Battery Backup Time at Full Load (min) | 15 | |||
| Maximum Load Current (A) | 20 – 100 | |||
| Battery Bank | External | |||
|
UPS-IND K
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|
| Audible Noise (dB) | < 72, a 1 meter | < 75, a 1 meter | ||
| MTBF (h) | 233,000 | |||
| Operational Temperature (°C) | 0~40 | |||
| Relative Humidity | 0 ~ 95% without condensation | |||
| Maximum Operating Altitude (mamsl) | 2,000 at 100% & 3,000 at 96% | |||
| Cabinet | Electrostatic baked epoxy coated steel, indoor installation, blank front, auto supported (non modular), IP20, black color (optional IP31) | |||
| Dimensions, height x width x depth (mm) | 1800 x 1600 x 1000 | 1800 x 2200 x 1000 | ||
| Weight (kg) | 1400 | 1700 | 2300 | 2400 |
|
UPS-IND K
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|
| Conversion Type | Online Double Conversion, Microprocessor Controlled | |||
| Rectifier | Regulated solid state & IGBT Power Factor Corrector | |||
| Inverter Conmutation Elements | Static PWM Technology w/ IGBT transistors | |||
| Filters | Anti harmonics (2% RMS distortion) | |||
| Isolation Transformer | Dry transformer | |||
| Battery Status | Real time Online/Discharge information with 3% precision | |||
| Thermal Dissipation (kBTU/h) | 96.9 | |||
| Internal Bypass | Two: electronic (automatic) bypass, and manual bypass for maintenance/repair | |||
| Paralleling | n+1 up to 4 units | |||
| Certifications | CE-IEC 62040-1, CE-IEC 62040-2, ISO 9001: 2015 | |||
| Communication Interface | RS232, RS485, dry contact relay signal, SNMP Network Card or MODBUS, IEC-61850 compliant | |||
| LCD Monochromatic Screen | Backlight: Input/Output Voltage, Load Capacity, Battery Voltage, Operation Status, mimic panel | |||
| Dry Contacts | Inverter Operating, Inverter Failure, Statc Switch Failure, Normal Operation, Low Battery, Vent Failure, Rectifier Power Supply Failure | |||
| Alarm | Low Battery, Abnormal CA Input, Inverter Failure, No Power Supply, Battery Operating, Ground Failure, Alternative Line Transference, Overheating | |||
| Protection | Low Battery, Overload, Short Circuit, Overheating | |||